| Client |
Amburtec, Ambur and Pranjali
Projects Bangalore. |
| Project |
To demonstrate colour and odour removal
from tannery effluents |
| Role |
Consultants for the following
services |
|
1. Characterization of effluent quality |
|
2. Evaluation of existing oxidation ditch
system for kinetics |
|
3. Evalution of oxygen transfer capacity
of aerators |
|
4. Laboratory studies on enzyme induced
enhancement of treatment. |
|
5. Commissioning of enzyme added bio
system in existing plant. |
|
6. Design and constructin supervision
of pilot plant for tertiary treatment |
|
7. Commissioning and validation of pilot
plant for continuous operation. |
|
8. Handling the visits of Pollution control
Board personnel and officers |
|
9. Training the in-house staff for self-sustaining
of the pilot plant. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Status |
The assignment started in August 97 and
was successfully completed in April 98. |
|
Results |
The plant demonstrated for the first
time in the country that tannery effluent can be treated
to totally clear, colourless and odouless quality for
appearance of treated effluent like mineral water. Some
of the key parameters of the raw effluent and the treated
water quality obtained in the tertiary plant in the
field are as follows: |
| Parameters |
BOD |
COD |
pH |
Chromium |
Colour |
Odour |
SS |
| Raw
effluent |
900
/ 1500 |
2000
/ 3500 |
7.4
/ 8.3 |
35
/ 45 |
Grayish |
Offensive |
5000 / 10000 |
| Final
effluent |
7 / 10 |
140 / 210 |
7.4 / 7.6
|
BDL |
nil |
nil |
10 / 20 |
Samples taken during April 1998 after the pilot plant
demostration of our recommanded process at Thutthipet